ABL10000G Custom Linear Positioner
Description
Design Features
- Granite stage, stainless-steel carriage
- 1.5 m/s, 1.5 g with 5 kg payload
- ±5 µm flatness, straightness
- ±5 arc-sec roll, pitch, yaw
- Accuracy ±1 µm calibrated, ±0.6 µm repeatability
- 35 kg load capacity
- < 40 nm在销售ition stability
- 1.2 m travel stage shown
Specifications
Mechanical Specifications
ABL10000G | ||||||
---|---|---|---|---|---|---|
Positioning | Travel | 1200 mm |
||||
Accuracy | LT Standard | ±40.0 µm | ||||
HALAR(1) | ±1 µm | |||||
Repeatability | ±0.6 µm | |||||
Minimum Step Size | 100 nm | |||||
Geometric |
Straightness | ±5.0 µm |
||||
Flatness | ±5.0 µm |
|||||
Pitch | ±25 µrad (±5 arc sec) | |||||
Roll | ±25 µrad (±5 arc sec) | |||||
Yaw | ±25 µrad (±5 arc sec) | |||||
Dynamic | Maximum Speed(2) | 1.5 m/s | ||||
Maximum Acceleration(2) | 1.5g | |||||
Other | Maximum Force (Continuous) | See BLM-267-A; w/Motor Cooling | ||||
Load Capacity(3) | Horizontal | 35 kg | ||||
Side | N/A | |||||
Operating Pressure(4)(5) | 80 psi ±5 psig |
|||||
Air Consumption |
32-40 SLPM @ 552 kPa (1.13-1.4 SCFM @ 5.52 bar) | |||||
Moving Mass |
52 kg |
|||||
Stage Mass |
1600 kg (bridge assembly only; no risers) |
|||||
Material | Granite base; steel carriage; aluminum carriage optional |
|||||
Protection | Some protection |
- Available with Aerotech controllers.
- Speed and acceleration based on 5 kg load.
- Maximum load based on bearing capability. Maximum application load may be limited by acceleration requirements.
- To protect air bearing against under-pressure, an in-line pressure switch tied to the motion controller/amplifier ESTOP input is recommended.
- Air supply must be clean, dry to 0°F dew point and filtered to 0.25 µm or better; recommend nitrogen at 99.9% purity.
- Specifications are for single-axis systems measured 25 mm above the tabletop. Performance of multi-axis systems is payload and workpoint dependent. Consult factory for multi-axis or non-standard applications.
Note: To ensure the achievement and repeatability of the specifications over an extended period of time, environmental temperature must be controlled to within 0.25 degrees C/24 hours. If this is not possible, alternate products are available. Please consult Aerotech Sales Engineering for more information.